Answer:
Here is your Answer Bellow!
Explanation:
Wiring a doorbell button switch in the normally-open (NO) state is preferred because it is safer and more reliable than wiring it in the normally-closed (NC) state.
In a doorbell circuit, when the doorbell button is pressed, it completes the circuit and allows current to flow to the doorbell, causing it to ring. In the NC configuration, the button switch is always closed, and current flows through the circuit even when the button is not pressed. This can cause several problems, such as short circuits, overheating, and premature wear on the doorbell and other components in the circuit.
On the other hand, in the NO configuration, the button switch is open when it is not pressed, and no current flows through the circuit. When the button is pressed, it closes the circuit and allows current to flow, causing the doorbell to ring. This configuration is safer because it minimizes the risk of short circuits, overheating, and premature wear on the components in the circuit.
In addition to being safer, the NO configuration is also more reliable because it is less prone to false triggers. In the NC configuration, the button switch can be triggered by vibration, accidental contact, or other factors, causing the doorbell to ring unnecessarily. In the NO configuration, however, the button switch must be deliberately pressed to trigger the doorbell, making it less likely to ring accidentally.
Overall, wiring a doorbell button switch in the normally-open state is the preferred configuration for safety, reliability, and durability.
Wiring a doorbell button switch in the normally-open (NO) state is preferred because it is safer and more reliable than wiring it in the normally-closed (NC) state.
In a doorbell circuit, when the doorbell button is pressed, it completes the circuit and allows current to flow to the doorbell, causing it to ring. In the NC configuration, the button switch is always closed, and current flows through the circuit even when the button is not pressed. This can cause several problems, such as short circuits, overheating, and premature wear on the doorbell and other components in the circuit.
On the other hand, in the NO configuration, the button switch is open when it is not pressed, and no current flows through the circuit.
Learn more about configuration on:
https://brainly.com/question/13410673
#SPJ1
Your load voltage and arc voltage measurement should be
Answer:
taken at the same time to ensure accurate results.
Explanation:
A 35-ft long solid steel rod is subjected to a load of 8,000 lb. This load causes the rod to stretch 0.266 in. The modulus of elasticity of the steel is 30,000,000 psi. Determine the diameter of the rod (precision of 0.00)
Answer:
The diameter of the rod can be determined using the following formula:
Explanation:
d = sqrt(4L / (pi * E * delta))
where:
d = diameter of the rod
L = length of the rod = 35 ft
E = modulus of elasticity of the steel = 30,000,000 psi
delta = elongation of the rod = 0.266 in
First, we need to convert the length of the rod and elongation to inches to maintain consistency with the units of E:
L = 35 ft * 12 in/ft = 420 in
delta = 0.266 in
Substituting the given values into the formula:
d = sqrt(4 * 420 / (pi * 30,000,000 * 0.266))
d = 0.615 in (rounded to 0.01)
Therefore, the diameter of the steel rod is 0.62 inches (rounded to 0.01).
A blocked drain on a pressure-reducing valve will
A) Result in no reduction of pressure
B) Prevent flow from the outlet of the valve
C) Block the inlet of the valve
D) Drop system pressure to zero
Answer:
Yes! I can Answer that!
Explanation:
C) Block the inlet of the valve.
A blocked drain on a pressure-reducing valve can prevent the valve from functioning correctly by blocking the drain line that is used to relieve excess pressure from the valve. As a result, the inlet of the valve can become blocked, causing the valve to malfunction and preventing it from reducing pressure. It is important to keep the drain line clear to ensure that the pressure-reducing valve works properly.